Notes on configuring the MC9090G terminals

Notes on configuring the Motorola (Symbol) MC9090G terminals

1)  Install ActiveSync 4.1 on your PC. (only necessary on first use)

2)  Install the Wavelink TE Application on your PC. (only necessary on first use) 

3)  Connect CRD9000 single bay cradle to PC using USB cable, the power supply is not strictly necessary unless charging required. 

4)  Switch on MC9090G and ensure it's at the Windows desktop with no applications running.

5)  Place MC9090G into cradle, it will beep and you will see a PC screen asking type of connection, choose "No" and press “Next” button.



 







6)  On ActiveSync window there will be a button "explore"... choose this. 










7)  A Window will open showing the file system of the hand held terminal. 

8)  Double tap the Applications folder within this window.

9)  Copy ALL the files in the "Hand Held RF Terminals - files to copy to Applications folder" folder on the PC to the "Applications" folder you just opened on the MC9090G. Overwrite if prompted, and if asked to convert from PC format to Windows Mobile format, say "Yes". Now close the window showing the files in “Applications” on the hand held terminal. 

10) Run Wavelink TE application on PC .... shortcut will now (after the install) be on PC desktop. The one illustrated below is the same , however the text below the icon will read “Wavelink MC9000 Telnet CE”

 

 

 



11) Import desired configuration file from "Wavelink TE configs" folder on PC by choosing the Import/Export Settings button on the window as here…

 


 



 

 


















Select the file from your PC that you were issued with when you initially configured the MC9090G. Then press “Open”

 

 




12) Make sure that your terminal isn’t running the TE application. It should be at the AppCenter desktop. If it is running TE then quit by pressing BLUE, then CTRL, and A keys, select Yes button (password is QUIT).

13) Press "Config Only" button on Wavelink screen.











14) Select OK when done.

15) Reboot terminal by removing battery, hold power and trigger, then release and replace the battery.

Saturday, 12 January 2008

Red Prairie Key Codes

F10 is set to ^X 0 (CTRL-X 0)
F3 is set to ^X 3 (CTRL-X 3)

VT100 emulation

# Extended Keys
0x2100 ^X 1 # FN1 Ctrl-X 1
0x2200 ^X 2 # FN2 Ctrl-X 2
0x2300 ^X 3 # FN3 Ctrl-X 3
0x2400 ^X 4 # FN4 Ctrl-X 4
0x2500 ^X 5 # FN5 Ctrl-X 5
0x2600 ^X 6 # FN6 Ctrl-X 6
0x2700 ^X 7 # FN7 Ctrl-X 7
0x2800 ^X 8 # FN8 Ctrl-X 8
0x2900 ^X 9 # FN9 Ctrl-X 9
0x2000 ^X 0 # FN10 Ctrl-X 0
0x1700 ^X ^P # UP Ctrl-X Ctrl-P
0x1500 ^X ^B # LEFT Ctrl-X Ctrl-B
0x1800 ^X ^N # DOWN Ctrl-X Ctrl-N
0x1600 ^X ^F # RIGHT Ctrl-X Ctrl-F
0xC000 ^X h # HELP_KEY Ctrl-X h
0xC000 ^X H # HELP_KEY Ctrl-X H
0xD200 ^X a # ACCEPT_KEY Ctrl-X a
0xD200 ^X A # ACCEPT_KEY Ctrl-X A
0xD300 ^X q # QUERY_KEY Ctrl-X q
0xD300 ^X Q # QUERY_KEY Ctrl-X Q
0xD500 ^X p # PRV_KEY Ctrl-X p
0xD500 ^X P # PRV_KEY Ctrl-X P
0xD600 ^X n # NXT_KEY Ctrl-X n
0xD600 ^X N # NXT_KEY Ctrl-X N
0x2000 ^X e # FN10 Ctrl-X e
0x2000 ^X E # FN10 Ctrl-X E

Monday, 10 September 2007

Wednesday, 16 May 2007

Loading Operating System onto a Symbol MC9090

Install the file "9090c50BenDC010402.exe" on your PC/Laptop.

Ensure ActiveSync is NOT running.

Connect a powered cradle to the laptop using either a serial cable or USB cable.

Start the MC9090G in IPL mode, by

Partially eject the battery

Press and hold the trigger and the power button while reinserting the battery until the MC9090 boots into IPL mode

Release the power button but continue to hold the trigger

Insert the MC9090 into the cradle then release the trigger

If you are using USB you will be prompted by the PC/laptop for a driver, point it at

C:\program files\symbol\tcm2\usb driver

On the PC/laptop

Click on "Start", "Programs", "Symbol device configuration packages", "MC9090c50 v1.4" and "TCM"

Click on the "load terminal" icon on the menu bar, you now need to download the hex files to the terminal one by one.

Browse to the "Hex Images" folder where the DCP is installed. You need to download the partition table file FIRST and the splash screen LAST, see the release notes if you are unsure which file is which.

After each file is installed you will need to reboot the terminal into IPL mode

Friday, 22 December 2006

Head cold warning on Zebra Printers

The command for this is ^MWn

Send this in any label format or make txt file as below and send to printer

^XA
^MWn
^XZ
~JUS

The ~JUS is just to save settings before turning off.

Very important switch printer off then back on again before command will work

Tuesday, 12 December 2006

Citrix ICA client - notes for MC9090G install

Trying to start the ICA client, the internet explorer opens at address http:\localhost and shows the following text:

>>>>>>>
The Windows CE Web Server is enabled on this device.

This file is a placeholder and should be replaced. Please see your Platform Builder docs or our web site at http://msdn.microsoft.com/library/default.asp?url=/library/en-us/wceinet/htm/webserv.asp.

More information on the Windows CE is available at http://www.microsoft.com/windows/embedded/ce.
<<<<<<<

What can I do to get to the main menu?


The solution is to disable the Windows CE Web Server.

In Win CE 4.1 You have to open a command prompt and then use services.exe to stop the service:

\> services stop htp0:

Where : is Shift Func R

Now the ICA client will start.

Friday, 8 December 2006

Some remap codes for MC9000 terminals, with Wavelink TE

9800:\4900
A000:\5100

This makes

Shift FUNC 6 = CTRL UPARROW
Shift FUNC 7 = CTRL DOWNARROW

And therefore they mimic the older Wavelink terminals.

The program exit key is 0029 which is ALT A